Welcome to Tesla Motors Club
Discuss Tesla's Model S, Model 3, Model X, Model Y, Cybertruck, Roadster and More.
Register

Search results

  1. G

    Firmware 1.34.3 issues

    Battery also gets partially charged via Off Peak overnight - which is good because it then feeds back into the morning Shoulder period (the period between Off Peak and Peak) before the Solar wakes up.
  2. G

    Firmware 1.34.3 issues

    Yes 1.34.3 is definitely bug ridden in the Cost Saving Mode. What is happening now is the PW2 is discharging into Off Peak periods. What is even worse is the PW2 is discharging into the same Off Peak period that it charged from. Just sending power into and out the PW2 during the same period...
  3. G

    Firmware 1.34.3 issues

    Yes would be nice if the App prompted to Save Changes Y/N - extra step but save some pain
  4. G

    1.9.1 is out

    Yes 1.9.1 (did that update from a phone). In Sydney we have a pretty solid 3G/4G network. The Tesla Gateway drives a "neurio" device with multiple inputs and has a SIM and aerial. The installer said the SIM has been paid for first 10 years by Tesla. Using this gateway takes out any support...
  5. G

    1.9.1 is out

    It has now settled into 1 update per hour at one minute to the hour (Sydney time) - which is very convenient
  6. G

    1.9.1 is out

    The Gateway can only tell what current is flowing to and from each endpoint. ie is power going in or out of each device (via inductively coupled Current Transformers). The Gateway and hence the App can't really tell where the electrons are going once there are more than two endpoints receiving...
  7. G

    1.9.1 is out

    All working fine on 1.9.1 Max charge rate from Grid 1.7kW (Single PW2)
  8. G

    1.9.1 is out

    Hi - I am running App version 3.2.0 and Firmware 1.191 I am only controlling the PW2 via the iPhone App. The setting on the PW2 only updates hourly (at the same minute each hour) - so there will be a delay after you change the App Reserve setting. I can't comment about your firmware version...
  9. G

    1.9.1 is out

    Hi 1.9.1 is also working for charging from the grid - looking good for the fix
  10. G

    1.9.1 is out

    Now have 1.9.1 Have tested dropping the reserve down to force deeper discharge - this now works but the update time has now changed (ie used to change settings hourly on the hour). Have now cranked the reserve level right up to see if I can force charging the PW2 from the grid - will let you know
  11. G

    Bugs with the new 1.9.0 OTA for Powerwall 2

    Tech support contacted me yesterday to advise: - issue I logged last week was associated with the now "known" 1.9.0 Firmware bug - they were not going to downgrade my firmware version as a new Firmware was imminent - the firmware update would be applied remotely and would not require any action...
  12. G

    Powerwall 2 Firmware: 1.9.0

    Yep - that's the symptoms - PW2 now totally ignores the App settings. They basically said if they couldn't issue a fix it in a reasonable time (1-2 days) they would downgrade the 1.9.0 installations giving priority to people who logged faults (as users who don't adjust the settings most likely...
  13. G

    Powerwall 2 Firmware: 1.9.0

    Currently running 1.9.0 but there is an issue where the Reserve Setting in the App is not being passed to the PW2. Multiple reports coming in from Customers. Get ready for either a rollback or an incremental update from 1.9.0