  1. J

    Grid profile recommendation--48 IQ8PLUS-72-2 US Microinverters w/Two PW2s

    Thank you for your feedback, but I believe most users on this board probably aren’t “average”. You’re right..4 or 5 minutes don’t really matter, but I do enjoy learning about how the system works, tweaking it, and comparing my experiences with others on here. If you do a search on here, there...
  2. J

    Grid profile recommendation--48 IQ8PLUS-72-2 US Microinverters w/Two PW2s

    Yes, I can shutoff the grid breaker and production seems nice and smooth. It ramps back up very quickly (in a few seconds) and starts charging the PW2s. On some of the other profiles I tried, production was bouncing all over the place.
  3. J

    Grid profile recommendation--48 IQ8PLUS-72-2 US Microinverters w/Two PW2s

    One more thing, when reviewing the Grid reports, I noticed for the Louisiana one that this was set to "Yes". I haven't seen that in any of the other profiles I've looked at. "Loss of phase detection enabled Yes"
  4. J

    Grid profile recommendation--48 IQ8PLUS-72-2 US Microinverters w/Two PW2s

    Thanks for the response. Yes, I'm monitoring the frequency while off grid. When the PW2s are at 100%, or in the 90s, my frequency is at 62.5, then it slowly tapers down after that. I went thru the logs today, and noticed on the days when I switched to the Louisiana profile (and was still...
  5. J

    Grid profile recommendation--48 IQ8PLUS-72-2 US Microinverters w/Two PW2s

    Thanks for the reply. With the grid connected. The only way I can get the Microinverters to start producing again is to change the profile and then wait until the next day.
  6. J

    Grid profile recommendation--48 IQ8PLUS-72-2 US Microinverters w/Two PW2s

    What's the recommendation these days for a grid profile with a quick restart (less than the 5 mins of the IEEE 1547 default profile) for use with the IQ8 microinverters and the Powerwalls? I'm using USVI-IQ PW2 right now as it has a 10 sec reconnect time and it seems to be ok, but is there...
  7. J

    New install—error after utility meter swap—Site shutdown circuit triggered. All Powerwalls and Powerwall+ solar inverters are disabled.

    Hi, I recently had two powerwalls installed, and everything was working fine until a few days ago when the utility company cut power to replace my meter. Ever since then, my Powerwalls have been stuck at 21% charge and won’t charge/discharge, so all my solar power is just going to the grid...