Welcome to Tesla Motors Club
Discuss Tesla's Model S, Model 3, Model X, Model Y, Cybertruck, Roadster and More.
Register

Search results

  1. C

    SCE: TOU-D 4-9pm or TOU-D Prime

    Good call thanks, I thought I had cut out all the PII :O That's reassuring, I certainly have enough storage that I can export during peak.
  2. C

    SCE: TOU-D 4-9pm or TOU-D Prime

    Well, I guess this is finally happening. The price increase is quite a bit, so I'll have to see what the best new configuration is for my power walls. I just got this notice today from SCE:
  3. C

    SCE Rate Plans changing 3/1/19?

    Well, I guess this is finally happening. The price increase is quite a bit, so I'll have to see what the best new configuration is for my power walls. I just got this notice today from SCE:
  4. C

    Powerwall 22.18 Firmware

    { "start_time": "2021-05-27 13:13:13 +0800", "up_time_seconds": "9099h29m44.625900249s", "is_new": false, "version": "1.48.1", "git_hash": "4533876fabf39dbbef588c6e5dc52e6048e0f261", "commission_count": 1, "device_type": "hec", "sync_type": "v1" } 1.48.1 lolol Oh well, I run self powered. No...
  5. C

    SCE Rate Plans changing 3/1/19?

    Almost two years exactly I re-checked the rate calculator and it's even worse compared to my original post. Since then I've added a 3rd powerwall and more solar to max out my inverter, which means the rate comparison tool isn't 100% accurate for me. I'm nearly 100% self powered these days...
  6. C

    Powerwall 2 Available Energy After 2 Years

    Not sure if this is affecting you, but it's an easy thing to check. One thing I have noticed in my install is that the canbus wiring was a bit shoddy from my installers and caused a powerwall to not register correctly. They're mounted in the corner of my garage with the status lights facing...
  7. C

    [Corona, CA] Local Model Y Owners

    Hey All, I wanted to see if there were any Model Y owners local to Corona, CA that wouldn't mind me dropping by to look at the car in person? I want to compare some dimensions with our current Honda CRV and to see in general what the car looks like. Feel free to DM me if you're open to this!
  8. C

    SCE Rate Plans changing 3/1/19?

    I have a 10.89 kW DC system. (33x 330W panels) I'm not sure how SCE calculates these values, as my current bills show that I actually don't have any energy credits. My guess is that it goes off of a full year TOU cycle. My current cycle ends in June, so we'll see if the numbers drastically...
  9. C

    SCE Rate Plans changing 3/1/19?

    I'm debating on whether or not to add a bit more solar to my existing setup this year (still 26% credit). We do have an EV and 2x Powerwalls already. When I get pushed off of TOU-D-A my rates will jump quite a bit per year:
  10. C

    Problems with Home Energy Gateway App

    You can explicitly turn off wifi on the gateway? How does one go about this, that would be great!
  11. C

    Has monitoring.solaredge.com also stopped working?

    Both are working for me as well. Android app and mobile from SoCal.
  12. C

    SolarEdge Inverter Monitoring Interval

    Are you sure that it's using the lan connection for data? I had both a cell card and ethernet, I had to switch the data connection to ethernet for the higher speeds to take effect.
  13. C

    My proposed system can't power my AC

    When I ran my test I didn't check how much solar I was producing unfortunately. I'd have to do more testing around that.
  14. C

    My proposed system can't power my AC

    When I say "fire up" I mean the AC condenser. At no point in my experiments did the powerwalls stop producing power or shut down. Without solar, and 100% on battery power the house browns out (even with a properly rated and installed SureStart) When the house browns out the thermostat...
  15. C

    My proposed system can't power my AC

    It would be my regular house loads, so probably ~1kW It doesn't help that my unit is 13 years old, I'm sure the starting current has gone up since it was new. Once it kicks the bucket I'm definitely moving to an inverter/variable speed unit.
  16. C

    My proposed system can't power my AC

    I bought mine from here: Sure Start SS1B16-32SN (16-32 RLA) – Ziller Electric I use it on a 5 ton AC 2006 Trane XR 13 LRA 148 RLA 25 With 2 powerwalls and the soft start the system won't fire up. However, if my solar is producing the little bit of extra power is enough to get the whole...
  17. C

    Powerwall Install Design

    I see two options: 1) Derate your main breaker further and adhere to the 120% rule 2017 NEC 705.12(B)(3)(b) You would need to do a load calculation and submit that to make sure this option is available to you. I assume you have a 7.6kW inverter that puts out 32A The next size up is a 10kW...
  18. C

    Powerwall Install Design

    Both of you would be correct here, I completely forgot about that. I almost always see the 120% rule mentioned so I forget about the other options. The gateway is indeed on a 125A breaker.
  19. C

    Powerwall Install Design

    While I do value @wwhitney's posts here, he's quite knowledgeable, I would defer to your AHJ. They are the source of truth. My dad got the same setup permitted with two powerwalls and 50A of solar backfeed, he's in LA county (vs me in Riverside county) his inspectors passed it too. In reality...
  20. C

    Powerwall Install Design

    My install got signed off by my AHJ so it worked out... But from what I understand since the batteries don't back feed to the grid (or at least aren't supposed to) they aren't considered in the backfeed calculations. (This is what my installer told me, didn't verify with the inspector since...
  21. C

    Powerwall Install Design

    I like this final plan, the only thing I would add is to go up one more size on the generation panel in case you decide to add another powerwall down the line. It's very cheap to get a 200A panel for the generation side that would allow 60A of solar + up to 4 additional powerwalls at 30A each...
  22. C

    Supercharger - Corona, CA (LIVE 29 Mar 2019, 20 Urban stalls)

    $273k for 14 stations, works out to just under $20k per station. That stuff ain't cheap!
  23. C

    Supercharger - Corona, CA (LIVE 29 Mar 2019, 20 Urban stalls)

    Yes, there is one going in by the Target in the crossings. Drove by yesterday, but it was a night and couldn't see anything good. Corona, CA | Tesla
  24. C

    Powerwall 2 + UPS Connundrum - and solution

    @wbhokie I was able to do a bit more testing this afternoon. I shut off my main breaker and let the powerwalls takeover the house. Solar was on, and putting out 4.8kW of power, 4.2kW of which was going to the batteries. At 97% the AC frequency went high and the inverter detected that and...
  25. C

    Powerwall 2 + UPS Connundrum - and solution

    Well I purpose bought these UPSs because my monitors are quite sensitive to the power cutover. They would turn off and back on during a flip. Since installing these I haven't had any of those issues, and we've had 2 unplanned outages since. So for me, that's a win. In terms of "kicking off" -...
  26. C

    Powerwall 2 + UPS Connundrum - and solution

    Yep, they're working great. I haven't done a full suite of testing though. Not sure how they'll perform during a daytime outage when the powerwalls are frequency shifting to shut down the inverter. For a standard flip they've proven themselves for me.
  27. C

    Is it time to cancel my power wall?

    Very off topic, but hello fellow Coronian :P /continue thread
  28. C

    Powerwall/Solar Edge behavior in power outage

    I too have a SolarEdge HD 7600 inverter. Mine will shut down when the power gets flipped but the readout on it says it will resume in 5m. After the 5m is up the inverter fires up and resumes. When the batteries get full the powerwalls bump the frequency and the inverter slows down. It all...
  29. C

    Powerwall 2 + UPS Connundrum - and solution

    I ended up just getting a few of these: https://smile.amazon.com/AmazonBasics-Standby-UPS-400VA-Outlets/dp/B073Q48Z95/ To plug monitors and a few computers into, things that were very sensitive to power fluctuations. During a transfer event on the powerwall these kick in for half a second and...
  30. C

    Solar Comps in Los Angeles

    Correction Notice 1: Installed equipment does not match plans (It didn't) All breakers must be labeled All empty panel locations must be covered (There were a bunch of blanks in the old panel that never got covered, I personally asked for this one for months) Correction Notice 2: Installed...
  31. C

    Solar Comps in Los Angeles

    My opinion on them started out great, I really liked them. But they've dragged out wrapping up all the final details. I got my powerwalls installed first week of July, the permits STILL haven't been signed off and we've gone through 3 revisions now. They were supposed to schedule inspectors to...
  32. C

    Tesla: we need more control over our PowerWalls

    It's not exactly "high tech", but yes I have a software for that: National and Local Weather Radar, Daily Forecast, Hurricane and information from The Weather Channel and weather.com I subscribe to rain/storm updates for my area and it emails me in advance. IFTTT helps your apps and devices...
  33. C

    Solar Comps in Los Angeles

    I second this!
  34. C

    Powewall peak kw demand question - Zero Net Energy Home

    I really really really wanted to go down this route, but it's so freaking expensive. I couldn't bring myself to do it, I'll likely end up going with straight mini splits :|
  35. C

    Powewall peak kw demand question - Zero Net Energy Home

    According to this spec sheet: https://dms.hvacpartners.com/docs/1009/Public/00/PDS286B-02.pdf Page 7, far right column Your 3 ton condenser calls for a 35A breaker max. In theory you could install a 30A and be within the constraints of the single power wall.
  36. C

    Anyone get SGIP $$ back yet?

    Sweet I got my step 2 check on Saturday in the mail, $9,280 for two powerwalls. AWESOME
  37. C

    Powerwall 2: SGIP/Incentives

    I'm on SCE and these are the subject lines for all the emails I got regarding them and sgip: SGIP Application Selected Notification - 03/24/18 SGIP RRF Review Receipt - 03/28/18 SGIP Confirmed Reservation Letter - 04/11/18 SGIP ICF Receipt - 08/27/18 SGIP ICF Approval - 09/19/18 They all...
  38. C

    Stormwatch Failure

    This is the alert I got: Arcadia is considered LA County, that's probably why you didn't get it.
  39. C

    Stormwatch Failure

    Mine is currently running storm watch as well. I can also confirm getting a high wind advisory from weather.com. So maybe it's working as expected? @Az_Rael raises a good point though, maybe it gets it's data from the utility and not weather events? If that's the case it would be really nice...
  40. C

    Tesla / Solar City Horrible Yelp Reviews?? What is y'alls experience with their PV installs?

    I've been watching your saga since the beginning of this year, and it totally sucks man. I thought I was going to do poorly going with another installer but it seems like it was less painful in the end (albeit more money). I signed my contract in March, got my solar in May, Powerwalls in July...
  41. C

    Powerwalls + Air Conditioning

    Oh I have looked into it, I got a few quotes to re-do the house with mini splits or a more efficient conventional setup. The quotes ranged from $18k - $24k not anywhere remotely in the cards right now. Especially considering the current AC setup works great, it just draws a lot of power.
  42. C

    Powerwalls + Air Conditioning

    I do have the name plate rating, but I also have a soft starter attached to the condenser. Hyper Engineering | Single Phase I need to measure ahead of the soft starter to get an accurate reading. I guess that makes sense in terms of most accurate measurement, I'll borrow a scope and buy a...
  43. C

    Powerwalls + Air Conditioning

    Agree'd What's the best (re: most accurate for a reasonable sum of money) to measure the startup current of the AC? My cheap clamp on multimeter isn't fast enough, that's what I originally used to measure it.
  44. C

    Powerwalls + Air Conditioning

    So SCE is doing maintenance in the area today and I took the opportunity to do some more digging on why my setup can't fire up the AC condenser. And I made a little discovery.... The home has 10.89kW DC of solar on a 7.6kW AC inverter. When the home is off the grid the power walls with adjust...
  45. C

    Joined the club!

    I'm actually a little happy that it was two separate conduits now. With the sandwiching one battery gets much hotter than the other, so I'm going to un-stack them and put them side by side after I get my final inspection. Hopefully that should ease the heat gain of the battery that gets hot.
  46. C

    Joined the club!

    I got my ICF approval yesterday! Should be seeing a check in a few weeks. Very excited!
  47. C

    Firmware 1.22.1

    I got 1.22.1 this morning. Haven't really noticed anything different about this one.
  48. C

    NEM 2.0: Non-bypassable charges and Powerwall modes

    The timing of this post is incredible. I was literally thinking about this last night while I was looking at my bill. Same deal, ~2 months of solar with powerwalls. Only $70 banked in credit though :rolleyes: I had also switched my pool to run at night to use the "cheap" power, but I'm now...
  49. C

    LA installer

    I echo this sentiment, I did get my powerwalls quickly and I did make it into step 2 but I'm still hassling with their install. I called the city today about the whole situation and they ended up un-finalizing the permit, so hopefully that gives me more leverage to get them to come out and...
  50. C

    Powerwalls + Air Conditioning

    Heat Recovery Pool Heater | Compare To Solar Pool Heater | HotSpot Energy LLC